Supmea SUP-MPP1000 Multi-Parameter Analyzer

Previous 7 / 7 Next

Quantity
Add Quotation


The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

Characteristics

Integrated design: Easy installation, operation, and maintenance

Multi-parameter monitoring: turbidity, residual chlorine, pH, temperature, conductivity, dissolved oxygen, and ORP

High precision: Precision up to 0.1ˇ«1NTU of tap water, 0.001ˇ«0.1NTU for purified water

Self-protection: Built-in ingress detection and automatic protection to avoid accidental damage

Easy integration: Standard RS-485 Modbus-RTU protocol and remote data transmission

High availability: Suitable for a variety of outdoor measurements in cold and hot areas

High customization: Support unique customizations, including trademark, name, and cabinet appearance

PH /ORP: 0-14pH, ±2000mV

Turbidity: 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU

Conductivity: 1-2000uS/cm / 1~200mS/m

Dissolved oxygen: 0-20mg/L
 

  • Specification

Item Index Value
System working power (220±22)VAC, (50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4ˇć~+50ˇć
Working temperature 4ˇć~+50ˇć / -25ˇć~+50ˇć(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500-1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS-485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0-1NTU / 0-20NTU / 0-100NTU:0.001NTU 0-4000NTU:0.01NTU
Lower detection limit 0.02 NTU; 0.1NTU (0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2%or±0.02NTU; 2%or0.1NTUٍ0-4000NTUŁ©
Repeatability ≤3%
Response time T90≤120s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14 pH, ±2000 mV (ORP)
Resolution 0.01 pH, ±1 mV (ORP)
Accuracy ±0.1 pH, ±20 mV (ORP) or ±2%
Repeatability ±0.1 pH, ±10 mV (ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range
-20ˇć - 85ˇć
Resolution 0.1ˇć
Accuracy ±0.5ˇć
Repeatability ≤0.5ˇć
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m 
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485, 4-20mA

Multi-parameter analyzer