- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Autonics
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- KROHNE
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- RITTAL
- Accessories for Climate Control
- Climate Control
- Accessories for IT cooling
- Air-air Heat Exchanger
- Air-water Heat Exchanger
- Chillers
- Cooling units, Thermoelectric Cooler
- Direct Air Cooling (DAC) systems for multifunctional enclosures
- Enclosure heater with fan
- Fan-and-filter Units, Roof-mounted fans, Rack-mounted Fans
- Heaters
- Hose-proof hood to increase the protection category
- IT Cooling - Aisle Containment
- IT Cooling - IT Room Cooling, Chiller, Roof-mounted cooling units for cooling IT equipment
- IT Cooling - Liquid Cooling Package
- IT Cooling - Small Cooling Unit
- Modular Climate Control Concept - Cooling module "Blue e" Total cooling output 1.50 - 2.50 kW
- Modular climate control concept ¨C Climate control door VX25 for installing cooling modules
- Setra
- Siemens
- SIMEX
- Sondar
- Supmea
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
25, Jalan Chain Ferry, Taman Chai Leng, 13700 Perai, Pulau Pinang, Malaysia.
Supmea SUP-MPP500 Economy Multi-parameter Water Analyzer
| Previous | 5 / 7 | Next |
Characteristics
Integrated design: Integration configuration avoids flooding and ground moisture, and no space is occupied.
Multiple parameters monitoring: Offer multiple monitoring for turbidity, residual chlorine dioxide, pH, temperature, conductivity, TDS, dissolved oxygen, and ORP.
High precision: Long-term stable and accurate measurement in the order of tap water (0.1¡«1NTU) and purified water (0.001¡«0.1NTU).
Low maintenance: Provide remote control, like automatic sewage discharge and adjustment.
Equipment protection: Support built-in ingress detection to guard against damage by sudden device failure or breakdown.
Smart communication: standard RS485 Modbus-RTU protocol and device wireless data transmission channel.
PH /ORP: 0-14pH, ±2000mV
Turbidity: 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU
Conductivity: 0-20000uS/cm / 0~20mS/m
Residual chlorine/chlorine dioxide/ozone: 0-5mg/L / 0-20mg/L
Temperature: 0¡æ - 50¡æ
-
Specification
| Item | Index | Value |
| System | Power supply | (220±22)VAC, (50±1)Hz |
| Power consumption | ≤30W | |
| Cabinet size | 500mm*400mm*200mm | |
| Weight | about 12Kg | |
| Storage temperature | 4¡æ~+50¡æ | |
| Operating temperature | 0¡æ~+50¡æ | |
| Working humidity | ≤95%RH (no condensation) | |
| Inlet water flow | 0.03~0.06m³/h | |
| Inlet pressure | < 0.3MPa | |
| Display | Color Touch Screen | |
| Communication interface | RS-485 Modbus RTU communication protocol + wireless interface | |
| Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU |
| Resolution | 0-1NTU / 0-20NTU / 0-100NTU:0.001NTU 0-2000NTU:0.01NTU | |
| Detection limit | 0.005 NTU | |
| Zero drift | ≤1.5% | |
| Indication stability | ≤1.5% | |
| Accuracy | 2% or ±0.02NTU; 10% or 0.5NTU (0-2000NTU) | |
| Repeatability | ≤1% | |
| Response time | T90≤120s | |
| Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
| Residual chlorine/chlorine dioxide/ozone | Range | 0-5mg/L / 0-20mg/L |
| Resolution | 0.01mg/L | |
| Detection limit | 0.05mg/L | |
| Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
| Response time | ≤120 seconds | |
| Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
| pH /ORP(optional) | Range | 0-14 pH, ±2000 mV (ORP) |
| Resolution | 0.01 pH, ±1 mV (ORP) | |
| Accuracy | ±0.1 pH, ±20 mV (ORP) or ±2% | |
| Repeatability | ±0.1 pH, ±10 mV (ORP) | |
| Response time | ≤60 seconds | |
| Recommended maintenance period | 1-3 months | |
| Temperature | Range | 0¡æ - 50¡æ |
| Resolution | 0.1¡æ | |
| Accuracy | ±0.5¡æ | |
| Repeatability | ≤0.5¡æ | |
| Response time | ≤25 seconds | |
| Recommended maintenance period | 12 months | |
| Conductivity (Optional) | Range | 0-20000uS/cm£» 0-20uS/cm£¨Pure water sensor£© |
| Accuracy | ±0.8%F.S£» ±3%F.S£¨Pure water sensor£© | |
| Resolution | 0.01uS/cm | |
| Repeatability | ≤0.4%FS | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 3-6 months |