- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Autonics
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- KROHNE
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- RITTAL
- Accessories for Climate Control
- Climate Control
- Accessories for IT cooling
- Air-air Heat Exchanger
- Air-water Heat Exchanger
- Chillers
- Cooling units, Thermoelectric Cooler
- Direct Air Cooling (DAC) systems for multifunctional enclosures
- Enclosure heater with fan
- Fan-and-filter Units, Roof-mounted fans, Rack-mounted Fans
- Heaters
- Hose-proof hood to increase the protection category
- IT Cooling - Aisle Containment
- IT Cooling - IT Room Cooling, Chiller, Roof-mounted cooling units for cooling IT equipment
- IT Cooling - Liquid Cooling Package
- IT Cooling - Small Cooling Unit
- Modular Climate Control Concept - Cooling module "Blue e" Total cooling output 1.50 - 2.50 kW
- Modular climate control concept ¨C Climate control door VX25 for installing cooling modules
- Setra
- Siemens
- SIMEX
- Sondar
- Supmea
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
25, Jalan Chain Ferry, Taman Chai Leng, 13700 Perai, Pulau Pinang, Malaysia.
Total Phosphorous Analyzer: TP Analyzer Liquiline System
| Previous | 1 / 7 | Next |
This SUP TP Analyzer Liquiline System provides incomparable total phosphorus detection for wastewater treatment plants, drinking water facilities, rivers, pools, lakes, reservoirs, environmental monitoring stations, surface water monitoring, and other water treatment applications.
Characteristics
Low reagent consumption: Less than 3mL reagent consumption in a single measurement
Separation of toxic and non-toxic water: More accurate and stable measurement provided
Double optical path detection: Real-time calculation of absorbance for zero interference in the external environment of the optical system
Alarm of reagent's lack: Automatic detection when rthe eagent sample is insufficient
Automatic compensation of turbidity: Automatic compensation based on the turbidity of the sample to avoid interference
Automatic data upload: Upload key documentation automatically for compliance
Man-machine interaction: Linux system makes the interaction easy and intuitive with a touchscreen
IPv4 Network support: Compatible with IPv6 network and meets the communication requirements of TCP/IP protocol
USB and TF card support: Program upgrade, data export, and data storage upgradeare supported
-
Specification
| Measuring range | (0¡«100 / 200 / 500 / 1000 / 2000) mg/L |
| Error | 20% Range:±8%; 50% Range:±5%; 80% Range:±3% |
| Repeatability | ≤3% |
| 24h low concentration drift | ±5 mg/L |
| 24h high concentration drift | ≤3% |
| Minimum Maintenance Period | ≥168 h/time |
| Digital communication | RS232¡¢RS485¡¢RJ45 |
| Analog communication | (4~20)mA input; (4~20)mA output |
| Power requirements | (220±22)VAC£»(50±1)Hz |
| Ambient temperature | (5~40)¡æ |
| Size | 300mm×420mm×240mm (W×H×D) |
| Weight | £¼15 Kg |