- Allen-Bradley
- ASHCROFT
- New & Featured Products - HPS high-purity pressure gauge with Reed Switch
- New & Featured Products - S1 Pressure Transducer
- New & Featured Products - ZT12 High Purity Pressure Transmitter
- New & Featured Products - ZX12 High Purity Pressure Transmitter
- Pressure Instruments - Accessories
- Pressure Instruments - Diaphragm Seals-Isolators
- Pressure Instruments - Pressure Gauges
- Pressure Instruments - Pressure Sensors (Transducers/Transmitters)
- Pressure Instruments - Pressure Switches
- Pressure Instruments - SMART Transmitter Assemblies
- Temperature Instruments - MultiPoint Temperature Sensors
- Temperature Instruments - OEM Temperature Sensors
- Temperature Instruments - RTDs
- Temperature Instruments - Temperature Switches
- Temperature Instruments - Thermocouples
- Temperature Instruments - Thermometers
- Temperature Instruments - Thermowells
- Test Instruments - Calibrators
- Test Instruments - Hand Pumps-Controllers
- Test Instruments - Hydraulic Testers
- Test Instruments - Test Gauges
- Autonics
- Cosel
- Euromag
- eYc
- Finetek
- Huba Control
- Koyo
- KROHNE
- Maxwell
- MEKKO
- Prokits
- 3C Product Repair Tools
- Aid Tools
- Alignment Tools & Screwdrivers
- Ceramic Driver
- Crimpers
- Cutter
- Drill Bits
- Driver Set
- Electrical Pliers
- Fiber Optics
- Hex Key Wrenches
- Hex Nut Drivers
- Knives & Scissors
- Miscellaneous
- Plier
- Power Tools
- Precision Tweezers
- Punch Down Tools
- Socket Wrenches
- Soldering & Desoldering
- Storage Box
- Strippers
- Test Instruments
- VDE Insulation Tools
- RITTAL
- Accessories for Climate Control
- Climate Control
- Accessories for IT cooling
- Air-air Heat Exchanger
- Air-water Heat Exchanger
- Chillers
- Cooling units, Thermoelectric Cooler
- Direct Air Cooling (DAC) systems for multifunctional enclosures
- Enclosure heater with fan
- Fan-and-filter Units, Roof-mounted fans, Rack-mounted Fans
- Heaters
- Hose-proof hood to increase the protection category
- IT Cooling - Aisle Containment
- IT Cooling - IT Room Cooling, Chiller, Roof-mounted cooling units for cooling IT equipment
- IT Cooling - Liquid Cooling Package
- IT Cooling - Small Cooling Unit
- Modular Climate Control Concept - Cooling module "Blue e" Total cooling output 1.50 - 2.50 kW
- Modular climate control concept ¨C Climate control door VX25 for installing cooling modules
- Setra
- Siemens
- SIMEX
- Sondar
- Supmea
- SURE INSTRUMENTS
- Suto
- Tsuruga
- VAISALA
- VE-PURE
- WELTEM
- Winters Instruments
TECH IMPRO AUTOMATION SOLUTION SDN BHD
25, Jalan Chain Ferry, Taman Chai Leng, 13700 Perai, Pulau Pinang, Malaysia.
+6012-466 1514
Supmea SUP-TRC400 Residual chlorine meter
| Previous | 1 / 3 | Next |
SUP-TRC 400 Residual chlorine meter has a built-in sensor, which has the characteristics of high measurement accuracy, fast response time and low maintenance cost.
Characteristics
Measure range:
Residual chlorine: (0~5) mg/L
Temperature: (0.1~40.0)¡æ
Load Resistance: ≤750Ω
Power supply: 220VAC
Communication :MODBUS RS485
-
Specification
SUP-TRC 400 Residual chlorine meter
| Product | Residual chlorine meter |
| Model | SUP-TRC400 |
| Measure range | Residual chlorine: (0~5) mg/L Temperature: (0.1~40.0)¡æ |
| Display | 7 inch touch screen |
| Protective box size |
Dimensions : 400mm×300mm×180mm Visual size : 155mm×87mm |
| Transmit output | (4~20)mA (optional) |
| Load resistance | ≤750Ω |
| Communication | RS485, Modbus |
| Environmental humidity | ≤95% no condensate |
| Power supply | 220VAC |
| Ingress protection | IP43 |
SUP-ERC 400 Residual chlorine sensor
| Measurement content | HCLO¡¢CLO2 |
| Measuring system | Microelectronics MEMS technology, special membrane structure |
| Measure range | (0~5£©mg/L |
| Accuracy | When ≤0.1mg/L, the absolute error is ±0.01mg/L; When ≥0.1mg/L, ±5% of the measured value or ±0.02mg/L (whichever is greater) |
| Resolution | 0.01 |
| Polarization time | When using for the first time, first pass water for 2 hours in chlorinated water, and then power on for half an hour. |
| Response time | Less than 30s after polarization is completed |
| Minimum conductivity | ≥100us/cm, can not be used for ultrapure water |
| Operating temperature | (0.1~40) ¡æ (No condensed water) |
| Temperature compensation | Pt1000 with built-in integrated automatic compensation |
| Max pressure | 4bar |
| Recommended flow rate | ≥0.03m/s in flow cell |
| pH range | (5~9) pH, below 5 will damage the membrane head |
| Maximum chlorine concentration | ≥5ppm |
| Power supply | Standard 24V DC±2V; optional 12V DC±2V |
| Power consumption | 1.56W |
| Digital communication | MODBUS RS485 |
| Cable length | Standard 3 meters, others can be customized |
| Probe weight | 210g |
| Thread size | NPT 3/4 |
| Connection method | 5-pin waterproof aviation plug |
| Moisture-proof material | PVC and Viton® O-ring seals |